DELTA PF

The DELTA PF cup is a hemispherical cup made from titanium alloy to treat primary acetabular cases. The primary stability is supported by retentive grooves, a PoroTi and hydroxyapatite coating and the hemispherical cup design.

Hemispherical cup design

Circumferential retentive grooves

Double coating PoroTi & HA

About

DELTA PF cup represents the gold standard for primary hip replacement.

Equipped with equatorial retentive grooves, the DELTA PF has a nominal 1.7 mm press-fit with respect to the acetabular reamer. This mechanical interference allows for an optimal 360° press-fit effect. The DELTA PF acts as a blind and cluster-hole cup. The three holes in the cranial area are occluded with removable plugs, that can be removed to allow further primary stabilization with bone screws. The LimaCorporate DELTA PF cup is available in sizes from 44 mm to 66 mm diameter in 2 mm increments. The DELTA PF is a modular and versatile cup: as part of the DELTA system, it allows a wide range of combinations and bearing options to provide a solution for any patient, both in primary and in basic revision surgery. Bearing options for the DELTA PF include Ceramic, X-Linked (X-LIMA) Poly, Vitamin-E enriched (LimaVit) Poly and Dual Mobility liners. All poly liners are available in both standard and protruded options. DELTA cups feature unique polar peg on all the liners to ensure correct alignment upon insertion into the shell. This helps avoid cross-locking that can lead to rim chipping and early failure of liners.

Sizing and Options

DELTA PF

DELTA PF Pressfit, hemispherical
Ti6Al4V + PoroTi + HA
Primary Cup,
Ø 44mm to 66mm
Liners BIOLOX®delta, LimaVit

DELTA PF

DELTA PF Delta Dual Mobility Option
32mm heads from 44mm cups
36mm heads from 50mm cups
40mm heads from 50mm cups

Clinical Papers

Bistolfi A, Ferracini R, Aprato A, Massè A, Daghino W, Lea S, Artiaco S, Lee GC.

Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up. J Orthop. 2020 Aug 28;22:397-401.

Fulin P, Pokorny D, Hert J, Sosna

A Results of 198 primary total hip arthroplasties using the Delta PF- FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up. BMC Musculoskelet Disord. 2020 May 19;21(1):311.

Zagra L, Anasetti F, Bianchi L, Licari V, Giacometti Ceroni R.

No difference in gait recovery after THA with different head diameters: a prospective randomized study. Clin Orthop Relat Res. 2013 Dec;471(12):3830-7. https://doi.org/10.1007/s11999-013-2926-6.

Resources

Contact us

Get in touch with us by filling out the form below.