DELTA Fins

The DELTA Fins cups are hemispherical press-fit cups that are highly functional in hip dysplasia cases. Longitudinal fins support the general torsional stability of the implant. DELTA Fin provide the smallest cups (OD42mm) within the DELTA portfolio.

Hemispherical cup design

8 longitudinal fins

Double coating PoroTi & HA

About

The DELTA Fins Hemispherical cementless acetabular cup is manufactured in Titanium alloy (Ti6Al4V) with double coating (PoroTi+HA).

The cup is designed to fit acetabular sockets and may feature surgically adequate morphologies. Special care is required in case of dysplasia and early revision cases. Equipped with equatorial vertical fins that penetrate the bone tissue, enhancing torsional stability and achieving optimal primary mechanical fixation, the Delta Fins cup has a 2 mm press-fit with respect to the last even acetabular reamer. This mechanical interference allows for an optimal 360° press-fit effect. Stronger fixation can be achieved through additional screw fixation using the 3 cranial holes with removable plugs available on the dome of the cup. The DELTA-FINS cup is available from 42 mm to 66 mm diameter with 2 mm increments between sizes, and can be coupled with BIOLOX®delta ceramic liners, standard and protruded X-Lima and LimaVit liners, and dual mobility system satisfying all market requirements.

Sizing and Options

Pressfit, hemispherical

Pressfit, hemispherical Ti6Al4V + PoroTi + HA
Primary Cup,
Ø 42mm to 66mm
Liners BIOLOX®delta, LimaVit

Delta Dual Mobility Option

Delta Dual Mobility Option 32mm heads from 42mm cups
36mm heads from 50mm cups
40mm heads from 50mm cups

Clinical Papers

Binazzi R, Dalla Pria P, De Zerbi M, Perdisa F.

Equatorial fins to enhance press fit of cementless cups with ceramic-on-ceramic and Met-Met articulation: positive experience with 3 different models. J Bone Joint Surg Br. 2012;94-B(Suppl XXV):14.

Binazzi R, De Zerbi, Pavlidou M, Nasta G.

Equatorial Fins to Enhance Press-Fit of Ceramic-on-Ceramic Cementless Cups in Dysplastic Arthritis: Positive Experience With 3 Different Models. Bone Joint J. 2013;95-B:(Suppl 15):136.

Necas L, Katina S, Uhlarova J, Colton CL. Slovakian

Arthroplasty Register – Survival analysis of total hip and knee replacement in Slovakia 2003 – 2011. Acta Chir. Orthop. Traum. Čech. 2013 Apr;80(Suppl.):1-85.