Enovis Logo
change profile

Click the button below to go to the homepage and view the site as a Patient.

generic background for product detail page

ProMade Hip

ProMade for highly complex acetabular cases 


A Dedicated Engineering Design Service to develop truly bespoke solutions for complex acetabular reconstructions.  


According to the anatomical defect, the implant can be developed to perfectly fit the damaged anatomy. 


Thanks to the 3D printing technology and know-how, compatibility with the Enovis portfolio is guaranteed, allowing a wide range of options to restore the specific biomechanics of that patient.  


More invasive reconstructions can be available, according to the specific clinical case. 



To open a Custom Case Request, VISIT THE PROMADE PORTAL

3D Printing Technology

Leveraging proprietary technology and long-lasting experience in 3D printing and Trabecular Titanium. This technology allows for design versatility to properly restore damaged hip anatomy, filling the defects considering the patient's clinical history and life conditions.

Modularity

Expanded modularity and connection with Enovis’ portfolio to provide a wide range of options on both the acetabular and femoral side, providing preoperative and intraoperative solutions to augment the biomechanical reconstruction.

Fully Planned Biomechanical Restoration

Using exclusive advanced software to provide reliable anatomic data for the surgeon to design, in collaboration with a dedicated engineer, the best bespoke biomechanical restoration for each patient.

About

For over a decade, the ProMade Team has partnered with surgeons to develop patient-specific solutions for complex orthopedic reconstructions, leveraging the capabilities of 3D printing.

Each case is planned using CT imaging data and clinical insights to precisely achieve the desired patient biomechanics. A dedicated online portal streamlines case submission and facilitates direct collaboration with engineers. The Engineering Team works closely with surgeons throughout the entire process, co-developing not only the implant design but also the surgical approach and technique.


To open a Custom Case Request, visit the ProMade Portal.


The ProMade solutions are driven by the design pillars of: Confidence in Primary Stability, Longevity through Natural Load Transfer, and a Fully planned Biomechanical Restoration. With these design pillars setting the foundation of the solutions developed, the extensive surgeon / engineer collaboration and the associated collaborative intelligence continue to advance solutions. For example, to reduce the associated morbidity related to the dissection for large flanges and screws of “classic triflange” designs the number and sizes of the flanges and number of screws in acetabular solutions have been reduced. In one example, the flanges were reduced in size and and number. The number of screws required were reduced from 13 to 8. In addition, the use of Trabecular Titanium has been expanded to allow more Natural Load Transfer and associated bone health. The same example, going from 7% of total volume to 30% of total volume.

Clinical Papers

Di Laura 2020 3D printing

The effect of metal artefact on the design of custom 3D printed acetabular implants

Perticarini 2020 JBRHA

Trabecular titanium tailored implants in complex acetabular revision surgeries: our experience at minimum 3 years follow-up

Romagnoli 2023 JOSR

Custom-made implants for massive acetabular bone loss: accuracy with CT assessment

Sculco 2022 HSS

The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium

Zanasi 2020 BMJ

Customised three-dimensional printed revision acetabular implant for large defect after failed triflange revision cup

Contact us

Get in touch with us by filling out the form below.