Enovis Logo
change profile

Click the button below to go to the homepage and view the site as a Patient.

generic background for product detail page

SMR TT Augmented 360 MB

Balanced by Design


SMR TT Augmented 360 MB aims to support surgeons to treat any glenoid bone loss case with a modular, defect-matching solution.

Evolved MODULARITY

Modular central peg and circular baseplate designed to provide a dialable, defect filling solution in line with SMR System legacy [1-3]

Reliable FIXATION

Multiple configurations with 3D printed TT Peg and Screws aim at optimizing placement through versatile implant orientation

Streamlined PREPARATION

Intraoperative experience does matter. The ASAP system provides on-axis glenoid preparation through our sleeve-based instrumentation, aiming at supporting a straightforward glenoid preparation and 360° placement of the implant

About

A circular baseplate design paired with a modular clinically proven TT peg [4-6] and prepared on-axis with the new ASAP Reamer & Drill System.

SMR TT Augmented 360 MB aims at supporting surgeons to treat any glenoid bone loss case with a modular, defect-matching solution. ASAP system aims at increasing reproducibility and at reducing intraoperative time, while TT aims at ensuring a long-term fixation, proven by its long clinical heritage [4-9].

[1] Kirsch JM, Khan M, Thornley P, Gichuru M, Freehill MT, Neviaser A, Moravek J, Miller BS, Bedi A. Platform shoulder arthroplasty: a systematic review. J Shoulder Elbow Surg. 2018;27(4):756-3. [2] Weber-Spickschen TS, Alfke D, Agneskirchner JD. The use of a modular system to convert an anatomical total shoulder arthroplasty to a reverse shoulder arthroplasty: Clinical and radiological results. Bone Joint J. 2015 Dec;97-B(12):1662-7 [3] Castagna A, Delcogliano M, de Caro F, Ziveri G, Borroni M, Gumina S, Postacchini F, De Biase CF. Conversion of shoulder arthroplasty to reverse implants: clinical and radiological results using a modular system. Int Orthop. 2013 Jul;37(7):1297-305. [4] Granville-Chapman J, Copas D, Robinson S, Walton M, Bale RS, Trail IA. The First Series of SMR AXIOMA-TT Early Experiences with an Innovative Trabecular Titanium Implant for Complex Glenoid Reconstruction. Shoulder & Elbow 2015;7(4):318-9. [5] A. M. Malhas, J. Granville-Chapman, P. M. Robinson, S. Brookes-Fazakerley, M. Walton, P. Monga, S. Bale, I. Trail Reconstruction of the glenoid using autologous bone-graft and the SMR Axioma TT metal-backed prosthesis. Bone Joint J 2018;100-B:1609–17. [6] Singh J et al. Survivorship of Autologous Structural Bone Graft at a Minimum of Two Years when used to address Significant Glenoid Bone Loss In Primary and Revision Shoulder Arthroplasty: A CT and clinical Review. J Shoulder Elbow Surg. Epub 2020 Jul. [7]* Marin E, Fedrizzi L, Regis M, Pressacco M, Zagra L, Fusi S. Stability Enhancement Of Prosthetic Implants: Friction Analysis Of Trabecular Titanium. Hip Int. 2012;403:427-8. [8]* Sollazzo V, Massari L, Pezzetti F, Girardi A, Farinella F, Lorusso V, Burelli S, Bloch HR, Carinci F. Genetic effects of Trabecular Titanium™ on MG-63 cell line: a genetic profiling evaluation. ISRN Mater Sci. 2011:392763. [9]* Benazzo F, Botta L, Scaffino MF, Caliogna L, Marullo M, Fusi S, Gastaldi G. Trabecular Titanium can induce in vitro osteogenic differentiation of human adipose derived stem cells without osteogenic factors. J Biomed Mater Res Part A. 2014:102A:2061–71. [10]* Devine D, Arens D, Burelli S, Bloch HR, Boure L. In vivo evaluation of the osteointegration of new highly porous Trabecular Titanium™. J Bone Joint Surg Br. 2012;94-B(Suppl XXXVII):201. *results from pre-clinical studies only.

Sizing and Options

SMR TT Augmented 360 MB is available in different options, both flat and wedged to treat glenoid bone loss. The modular eg in Trabecular Titanium is available in 3 different lengths for tailored fixation.

Clinical Papers

Schliemann B, Hartensuer R, Koch T, Theisen C, Raschke MJ, Kösters C, Weimann A.

Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg. 2015 Aug;24(8):1282-8.

Schliemann B, Seifert R, Theisen C, Gehweiler D, Wähnert D, Schulze M, Raschke MJ, Weimann A.

PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures. Arch Orthop Trauma Surg. 2017 Jan;137(1):63-71.

Rotini R, Cavaciocchi M, Fabbri D, Bettelli G, Catani F, Campochiaro G, Fontana M, Colozza A, De Biase CF, Ziveri G, Zapparoli C, Stacca F, Lupo R, Rapisarda S, Guerra E.

Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate. Musculoskelet Surg. 2015 Sep;99 Suppl 1:S1-8.

Resources