Flyer, EN
Is reconstructed (no change of the position of the femur to the acetabulum – retaining the offset) and therefore no change to bone quality.
Through further development of polyethylene to vitamys (vitamin E reduces the aging process of the polyethylene.
To optimise the bearing.
WHY BONE PRESERVATION? The requirements for artificial joint replacements are steadily increasing – the challenges often remain the same: Abrasion particles that cause osteolysis and stress shielding affect bone preservation, the quality of the joint replacement and the long-term stability of the prostheses. Solutions such as bone-preserving design, reduction of abrasion by novel technologies and reconstruction of the patient’s individual anatomy and biomechanics are addressed with the Bonepreservation system.
Optimys
The optimys was developed to enable the individual reconstruction of the patient’s anatomy, whereby the main construct is the femoral neck. The centre of rotation and the offset are independently retained, irrespective of the initial situation (varus or valgus of the femoral neck).
The design of the short stem and the reconstruction of the individual anatomy enable an improvement of the force distribution in the bone and reduce the stress shielding [1].
Innovation based on clinical evidence
Robert Mathys senior was the first to describe the isoelasticity of standard polyethylene cups, titanium RM cups and human bone [1]. The wear resistance was further improved through the introduction of vitamys (2009) reducing oxidation of polyethylene, by which osteolysis in the long term is virtually ruled out [2].
The quality of medical ceramics and the better wettability virtually rule out wear on ceramic-ceramic bearings and reduce the wear against standard PE to 1/10th1. The advantage of the ceramic-ceramic bearing with regard to wear is counteracted by the need for an additional metal fixation, with the consequence that there is an increase in stress shielding [2]. Thus today as an optimum solution Mathys recommends the hard-soft coupling, i.e. ceramys head and RM Pressfit vitamys (highly crosslinked PE stabilised with vitamin E).
Limacorporate S.p.A. / Mathys Ltd Bettlach, an Enovis Corporation affiliate, as a manufacturer of prosthetic implants, does not practice the medical profession. The choice of the most suitable surgical procedure and technique is the responsibility of the healthcare professional. Each Surgeon must evaluate the appropriateness of the implant technique they intend to perform in light of their own preparation, experience and clinical evaluation of each individual Patient.
This video is provided for the exclusive use of healthcare professionals. All rights to the content of the video are reserved pursuant to applicable law. Reproduction, publication and distribution by third parties are expressly prohibited without permission.
Product manufactured by Mathys Ltd Bettlach.
This product may not be compatible with other medical devices. Consult a healthcare professional before use. The manufacturer is not responsible for adverse outcomes if the product is used in situations where compatibility is not ensured. Please refer to IFU for further indications.
Please note that not all products are available and registered in every market. Please contact your Enovis’ Sales Representative for any further information.
Mathys Ltd Bettlach and Limacorporate S.p.A. are affiliates of Enovis Corporation.
Get in touch with us by filling out the form below.